BUILDING COMMISSIONING | Linkedin Poll Results and Statistics
We thought it would be interesting to start a page to consolidate the polls and commissioning statistics we collect on Linkedin, so here it is; … Read More
We thought it would be interesting to start a page to consolidate the polls and commissioning statistics we collect on Linkedin, so here it is; … Read More
Tendering can be very expensive, so clients use a formal pre-qualification / pre-selection process for selecting from a pool of bidders (contractors, suppliers, vendors, and … Read More
Within construction, a Request For Information [RFI], or Technical Query [TQ], is a formal contract document generally issued during the earlier stages of a project … Read More
When a [RFP] Request for Proposal or [RFQ] Request for Quotation is received requesting a Service Provider to provide a cost on a package of … Read More
This air-cooled chiller checklist can be used and completed throughout the project and its different stages covering: Once the pre-functional checks have been completed, the … Read More
Upon successful conclusion of each different data center commissioning level [0-7], a final certificate is required to be issued to the client and project team … Read More
Level 7, managed by the client CxA, is usually quick to complete; it concludes the overall project commissioning activities with the client/end-user accepting, during a … Read More
Level 6 of the Data Center Commissioning Process moves the project from the onsite commissioning phase to close out, turn over, and hand over. The … Read More
The Level 5 Integrated Testing for a Data Center aims to validate that all installed mechanical, electrical, fire, BMS, and controls systems, including equipment, operate … Read More
The Level 4 Data Center Commissioning Stage is usually where the General/Main Contractor hands over the testing responsibilities to the Client Commissioning Agent. The Commissioning … Read More
For Data Center Commissioning, the Level 3 Stage focuses on the following tasks and activities as listed below, proving that the systems have been installed, … Read More
Level 2 is the third stage/process to be completed after Level 1. Its focus is on verifying components, equipment, and materials after they have been … Read More
Within Data Center Commissioning, Level 1 is the second stage to be completed after Level 0. Its focus is on the Factory Testing Requirements and … Read More
Within Data Center Commissioning, Level 0 is usually the first stage to be started, it focuses upon the design and planning of the projects data … Read More
If you have ever wondered what the difference is between the LEED FUNDAMENTAL & ENHANCED Commissioning process, here is a table that lists out the … Read More
LEED Enhanced Commissioning is a process completed under the U.S Green Building Council Pre-Requisite V4 BD+C New Construction, with its aim being the same as … Read More
LEED Fundamental Commissioning is a process completed under the U.S Green Building Council Pre-Requisite 1 EA Module, with its aim being that all fundamental systems … Read More
Produced in the latter stages of the project by the construction project team, as-built drawings provide the final design and installation information of a project … Read More
Upon completion of any new CRAC [computer room air conditioning] Unit installation or modifications to an existing unit, there will be a requirement to complete … Read More
Read in conjunction with the overall project programme, look ahead schedules are used within the latter stages of the construction and commissioning phases of a … Read More